Battery Quality Analyser
- Testing at System Loading condition
- Impedance, Voltage, Temperature, Current and Capacity measurements (simultaneously or independently)
- User Friendly Software
High Performance Battery Quality Analyzer
Data Logger with Trend Analysis
Abundant Data Logging and Accurate Trend Analysis is available backed by Internal SD Card stored up to 7.5 million data in Text or Graphic mode
- The Battery Quality Analyzer is designed for measuring the internal resistance, opencircuit voltage, and terminal temperature of secondary batteries, including Lead Storage Cells (Lead -Acid batteries), nickel-cadmium batteries, lithium-ion batteries and nickel-metal hydride batteries.
- AC four-terminal method to measure the internal resistance by eliminating lead resistance and contact resistance to get the accurate results.
- Multiple display to show the internal resistance, voltage and temperature or voltage, current and temperature of the battery simultaneously.
- It has 99 sets of composite comparator function, which can be set at resistance and voltage values to get the reliable detection of battery deterioration.
- Pin type lead, which can easily contact the battery electrodes supplied as standard to get more accurate 4-terminal measurement.
- Clamp adaptor for DC current or AC current measurements.
Deterioration Trend Curve Analysis
Data Logger
Analyser
Applications
Field Management of UPS Back Up batteries in Industrial Systems -Telecom. Renewable Energy Power Plant (Solar, Water, Wind), Recreational, Marine, Airplane, Military, Electric Vehicle And Battery Related Industry (Manufacturer, Dealer) of most batteries including Lead Storage Cells (Lead-Acid batteries), nickel-cadmium batteries, lithium-ion batteries and nickel-metal hydride batteries.
Unsurpassed Performance in a Portable, Compact Package
Battery Health Analysis Information.
Comparator on Impedance, Voltage Auto Hold and Data Storage
Interface : USB Host / Client 2.0 Large 3.8" 320 x 240 pixel High
Resolution Monochrome LCD display.
Super Tool in Field Measurements and Management of UPS batteries
LCD Display
① Present Measurement Value when AutoHold mode
② Measurement Data and Time
③ Battery / Adapter Sign
④ Limit : Upper, Lower
⑤ Impedance Value Display
⑥ Unit of Measurement
⑦ Temperature Value Display
⑧ 4m Ω Convert key
⑨ “Unit-Cell-Times”display
⑩ Measurement Ave range and number of Averaged data
(displayed with Auto Hold)
⑪ Limit (Comparator) Pass - Warning-Fail
⑫ Auto Saving : When Auto Holding, Auto Saving is automatically
activated . Saved at Auto Record Memory in order, max 300
cells x 100 times measurement Record number : storage date
Recording Number.
⑬ Auto : Auto, manual ranging
⑭ Warning Sign
⑮ DC Voltage measurement
Electrical Specifications
- Impedance Measurement
Range : 4m ~ 4 (4 range)/1u resolution
Accuracy : 0.8%rdg 10dgts
Voltage Range : max 100V
Ah range : 5 ~ 6000 Ah - Voltage Measurement : Differential Input
Range : 4V, 40V, 300V (3 range)
Accuracy : 0.5%rdg 5dgts - DC Current (Float Current) Measurement.CT
Range : 40A/400A
Accuracy : 1%rdg 5dgts (CT Accuracy added) - AC Current (Ripple Current) Measurement.CT *Option
Range : 40A/400A
Accuracy : 1%rdg 5dgts (CT Accuracy added) - Temperature
Range : -10 C ~ 100 C/ 14 F ~ 212 F
Accuracy : 2 C 3.6 F
Battery Temperature Measurement : Internal Sensor.
Guaranteed Accuracy : 23 C +/-5 C, non-condensing - Capacity Measurement *WENS 900C only
% SOC, Efficiency, Ah, Wh - Safety : Certified EMS. LVD 61010-1 CAT II 300V DC
General Specifications
- Display : 3.8" Graphic Monochrome LCD Module(320*240)
- Input Method : Differential (Impedance, DC Voltage)
- Auto Power OFF : User Select at User mode
- Maxim Voltage Input : 300V DC
- Interface : USB 2.0 (Standard), Bluetooth (Option) Wi-Fi (Option)
- Operating Temperature : 0 ~ 40 C, 80% RH or Less
- Continuous Operating Time : 6 hours
- Power Supply : 7.2V, 2.7A NiMH Battery Pack (2)
- Line Power : 12V, 1A Adapter
- Dimensions : 107m (W) x 220mm (H) x 55mm(D) / 4.2”x 8.3”x 2.2”
- Weight (Main Unit only) : 1.2kg / 2.6 Ibs