Hybrid combination of the NIST proven “two-pressure” and “two-temperature” humidity generation

G2 Dew Point Generator

The G2 produces highly accurate humidity values, delivering a humidified gas stream, accurately controlled to a variety of user-selectable humidity parameters such as %RH, dew point, frost point, ppm, or vapor pressure. By accurately measuring the temperature and pressure at the point where the humidified gas is utilized, the G2 automatically adjusts for changes in dynamic conditions such as heat load or ambient pressure variation.With RH Systems’ hybrid humidity generation technique, the G2 is a true humidity reference instrument suitable for high accuracy calibration, product conditioning, and test applications.

High Flow Capability

With flow rate capacity up to 100 standard litres per minute, the G2 ensures your external volume or test chamber rapidly achieves a stable, homogeneous humidity condition based on your defined RH or dew point setting.

Embedded System For Control

Operations are automated with real-time, embedded control systems. Its setpoints are commanded and data is retrieved via robust serial communications. There are three fully capable, yet fully independent RS-232 serial ports, allowing for a variety of communication options.

Multiple External Temp Connections

By splitting the high-flow gas stream and feeding into three separate chambers, with each chamber controlled at a different temperature, three unique %RH values will be produced. The G2 computes the resulting %RH at each of these three chambers based on the three external temperature measurements.

Specifications

The G2’s specifications are outlined, below

Specifications
Generator Ranges
Frost/Dew Point* -25 … +20 °C
Relative Humidity 10 … 95 %RH
Flow Rate 5 … 100 l/min
Saturator Pressure Ambient … 12 bar (Ambient … 175 psia)
Measurement Ranges
External Temperature Sensor -50 … +100 °C
External Pressure Sensor 700 … 1,200 mbar (10.2 … 17.4 psia)
Performance
Dew Point Stability ≤ ±0.02 °C
RH Stability ≤ ±0.1 %RH
Pressure Stability ≤ ±1 mbar (≤ ±0.015 psia)
Saturator Temperature Stability ≤ ±0.01 °C
Flow Control ≤ ±0.5% of full scale
Response Time 10 … 90 %RH: < 5 min
Standard Features
External Temperature Sensor(s) Up to 3 simultaneous sensors, 100 ohm PRT
Pressure Sensor Internal with 1/8″ Swagelok connection
Saturator Water Level Automatic level control, 1/4″ Swagelok water inlet
Gas Connection (Inlet) 1/4″ Swagelok, internally pressure regulated
Gas Connection (Outlet) 1/2″ Swagelok, internally flow regulated
Control & Data Acquisition Optional touch screen controller and/or PC software
Size 6U, 19″ rack mountable module
Digital I/O 3 simultaneous, independent RS-232 connections
Additional Information
Power Requirements 208 … 240 VAC, 50–60 Hz, 1500 W
Input Pressure Max. 16 bar, oil free
Operation Temperature* -10 … +40 °C (must be higher than generated dew point)
Storage Temperature -20 … +50 °C
Humidity Max. 98 %RH, non-condensing
Weight and Dimensions (6U 19″ Module / With enclosure)
Height 267 mm (10.5″) / 318 mm (12.5″)
Width 483 mm (19″) / 533 mm (21″)
Depth 559 mm (22″) / 616 mm (24.25″)
Weight 53 kg (117 lbs) / 70 kg (154 lbs)
* Highest generated dew point is limited by ambient room temperature

 ​Talk to us

Customer Service: 0800 485 990 Phone: +64 3 348 5999

 ​​Postal Address

P.O. Box 8921
Riccarton
Christchurch 8440

 ​​Delivery Address

P.O. Box 8921
Riccarton
Christchurch 8440

Make an enquiry

Please enter your information and we will get back to you as soon as we can.

Please type your first name.
Invalid email address.
Please type in your phone number
Invalid Input
Invalid Input
Please type in your message